Type: | Deionzed Dm Plant |
---|---|
Usage: | Chemical Industry |
Motive Force: | Electric power |
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Industrial mixed bed resin ion exchange filter for water treatment system
Industrial mixed bed resin ion exchange filter for water treatment system
Both Mixed Bed Ion Exchange (MB) and Electrodeionization (EDI) are technologies used to produce Deionized (DI) Water.
Mixed Bed Ion Exchange (MB) uses ion exchange resins to remove dissolved ions from water. It is a traditional method that requires periodic chemical regeneration.
Electrodeionization (EDI) combines ion exchange with an electric field, allowing for continuous, chemical-free regeneration. It is a more modern, eco-friendly, and automated solution.
Technology | Principle | Regeneration | Use of Chemicals | Application Type |
---|---|---|---|---|
Mixed Bed Ion Exchange (MB) | Ion exchange resins absorb cations and anions | Manual regeneration required | Acid and alkali needed | Traditional method |
EDI (Electrodeionization) | Ion exchange + electric field | Continuous automatic regeneration | Not needed | More eco-friendly, modern method |
NOS. |
Items |
Information |
1. Anion and cation exchange demineralized water system Pre-treatment part |
||
1.1 |
Sand filter |
Remove turbidity, SS matter, organic matter, colloid, etc. |
1.2 |
Active carbon filter |
Remove color, free chloride, organic matter, harmful matter, etc. |
1.3 |
Water softener |
Soft water and reduce it's hardness. |
2. RO part |
||
2.1 |
High pressure pump |
Provide power for RO. |
2.2 |
PP filter |
Prevent large particles, iron, dust, SS matter, impurity into RO membrane. |
2.3 |
RO membrane |
Remves: lead, cooper, barium, chromium, mercury, sodium, cadmium, fluoride, nitrite, nitrate, and selenium. |
3. EDI system part |
||
3.1 |
PP filter |
Further removes ions in water. |
3.2 |
Booster pump |
Provide power for ion exchange system. |
3.3 |
EDI mode |
Further removes ions in water. Use Siemens/Canpure. |
4. Electricity control system |
||
4.1 |
PLC+Touch screen control system |
Japan Mitsubishi.siemens |
4.2 |
Electrivity components |
Import from German. Omron. |
4.3 |
Pipe and fitting |
Adopt domestic famous brands. |
![]() |
![]() |
EDI + reverse omsosis system
![]() |
![]() |
Process function description:
1.Anion and cation exchange demineralized water system use automatic control and semi-control .Pretreatment parts can adopt fiber glass or stainless steel material.
2.Industrial mixed bed resin ion exchange filter for water treatment systemfor waste water for softner has protected when no power, poor power, larger electrical current, leakage, short circuit.
3.Water treatment resinmixed bed demineralizers ion exchange resin is compact, easy installation.
4.Anion and cation exchange demineralized water system equipped with manual and auto control based on user needed.
5.Water treatment resinmixed bed demineralizers ion exchange resin produce as per ISO and SGS standard and main parts accessories have obtained CE certification.
6. All the plants will be commissioning well. Make sure don't have any problem when arrived site.
7.What we provide not only the good products, but also our whole team, the quality, experience, and service.
Ion Exchange Resin Beds - Where the ion exchange process occurs.
Pumps - To move water through the system.
Control Valves - To regulate flow and pressure.
Regeneration System - To clean and restore the resin.
Monitoring System - To track performance and quality.
Feed Water Tank - Holds the incoming water to be treated.
Item | Description |
---|---|
Equipment Name | Industrial Mixed Bed Resin Ion Exchange Filter |
Primary Function | Removes cations and anions from water to produce high-purity water |
Applications | Pharmaceuticals, electronics, food & drinking water, power plants, semiconductor industries |
Working Principle | Mixed bed resins remove soluble salts and other impurities through ion exchange, producing ultra-pure water |
Water Quality Requirement | Suitable for ultra-low conductivity water (typically 0.1~5 µS/cm) |
Capacity | Customizable according to client needs (flow rate range: 100L/h ~ 100m³/h) |
Resin Type | Combination of strong acid cation resin and strong base anion resin for efficient exchange |
Maintenance | Periodic regeneration of resins to restore ion-exchange capacity, using saline solutions |
Advantages | 1. Produces ultra-low conductivity water 2. Efficient ion impurity removal 3. Suitable for various industrial applications |
Customization Options | 1. Resin type based on water quality requirements 2. Optional automatic control system for monitoring water quality and flow rate |
Installation Type | Can be installed standalone or integrated with other water treatment equipment, containerized options available |
Model |
Capacity (LPH) |
Membrane Quantity |
Size(L*W*H) (mm) |
Weight (Kg) |
HY-RO-300 |
1500 GPD (300LPH) |
4040*1 |
1550*900*1820 |
150 |
HY-RO-3000 |
3000LPH |
4040*10 |
6000*800*2200 |
800 |
HY-RO-5000 |
5000LPH |
8040*4 |
7000*900*2400 |
1000 |
HY-RO-8000 |
8000LPH |
8040*8 |
8000*1000*2700 |
1600 |
HY-RO-10000 |
10000LPH |
8040*9 |
8200*1600*3000 |
2200 |
HY-RO-15000 |
15000LPH |
8040*15 |
8600*1700*3100 |
2800 |
HY-RO-50000 |
50000LPH |
8040*50 |
7000*2300*3800 |
8500 |
![]() |
![]() |
![]() |
Tips: one gallon=3.785 liters, 1m3=1ton=1000 liters, GPS,GPM When designing, we ultimately select based on the hourly water output flow rate. |
||||||
Different Water TDS(Total Dissolved Solids) compare and usage | ||||||
Raw water/Application | Bottled water, | City tap water | Softener water | Industry use (1st level) |
Industry use (2nd level) |
Industry use (3rd level) |
Bag water | ||||||
TDS Range | 2-10ppm | 100-1000ppm | 0.03mmol | Conductivity Range: 1--0.1 μS/cm |
Resitivity Range: 1----10MΩ/cm | Resitivity Range: 10----15MΩ/cm Or more higher: 18 MΩ/cm |
Direct Drinking | Yes | Yes/No | ||||
Cooking, human | Yes | Yes | ||||
consumption, washing | ||||||
Irrigation, Industry, | Yes | Yes | ||||
Animal Drinking | ||||||
For inudustry use: Condutivity beteen range 1-0.15us/cm or Resitivity 10-18 megohm. Different industry have different water quality requriement. |
||||||
1..Electricity supply:220V-480v, 50hz or 60hz,3 phases 2.Capacity: 500L/H to 50m3/hr. 20ft or 40ft containerized 3.Membranes :DOW(Dupont) or Toray or Vontron 4.UV sterilizer/Ozone generator, CIP washing system, anti-scale dosing system is for optional |
Buying Guides | ||
To find the most appropriate system/machine/plant for your use, please advise the following information ready | ||
· Product water flow rate ( m3/hr, m3/day, Liter/hr,GPM,GPD etc.) | ||
·Product water purpose(drinking, irrigation, industry process or others) | ||
· Feed Water TDS (Total dissolved solids). Is it from Borehole/salt/brackish/lake water | ||
· Iron | ||
· Manganese | ||
· TSS(Total Suspended Solid) | ||
· SDI(Silting Density Index)< 3 | ||
· Water must be free from oils and grease | ||
· Chlorine must be removed | ||
· Power (110/220/380V/415V/460V, 50 or 60 Hz) 3 phase. | ||
· It is necessary to make water analysis reprot for borehole water,lake water, seawater. | ||
· If soure water is tap water no need end to us TDS or water analysis report. | ||
Send your Inquiry Details in the Below, Click "Send" Now! |