Certification: | ISO9001, CE |
---|---|
Salt Rejection Rate: | 99.0% |
Application: | Industry |
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Please Attention
HY FACTORY OFFER YOU :
1: FACTORY DIRECT PRICE.
2: NICE QUALITY.
3: ONLINE PAYMENT.
4: SUPPORT REFUND AFTER YOUR INSTALLED THE PLANT IF THERE ARE ANY PROBLME.
5: AFTER SALES SERVICES 24/7
6. Letters patent
7. ENGINNER CAN BE OVERSEA INSTALLNATION
We have 2 factories +300 workers+ Qualified engineer+ Engineer Overseas service
Process function description
1. Ion exchange automatic control and semi-control .Pretreatment parts can adopt fiber glass or stainless steel material.
2.Demineralizer with mixed bed has protected when no power, poor power, larger electrical current, leakage, short circuit.
3.Ion exchange is compact, easy installation.
4.Demineralizer with mixed bed equipped with manual and auto control based on user needed.
5. Haiyuan mixed bed produce as per ISO and SGS standard and main parts accessories have obtained CE certification.
6. All the ion exchange mixed bed will be commissioning well. Make sure don't have any problem when arrived site.
7.What we provide not only the good products, but also our whole team, the quality, experience, and service.
Mixed bed ion exchange
A mixed bed ion exchange in water treatment uses two ion exchange regenerative systems formed in beads shape. It allows the cation and anions resin beads to mix together to remove impurities to produce high-quality water.
The mixed bed ion exchange acts as a deionizer and effectively removes the ions present in the water.
Efficiently combining both cation and anion resins in a single unit with compressed air for maximum purification results, HY mixed bed polishing systems generate ultra-high purity water with a near-neutral pH and low rinse water requirements. Cation resin exchanges hydrogen (H+) for cations (i.e. sodium), while anion resin exchanges hydroxyl (OH-) for anions (i.e. chloride). Hydrogen and hydroxide combine to form water, thereby purifying the incoming water. As the resins effectively remove the last traces of salinity and silica from pretreated water, a purer water is achieved (~18 Megaohm-cm, depending on feedwater quality) than what would otherwise result from conventional demineralization.
Although the process involves more intricate operating procedures (the resins require separation prior to regeneration) our mixed bed exchangers are ideal for polishing certain types of pretreated water streams for use in process condensate, semiconductor industry feed water, and many other applications.
Capacity: 5 m3 / h. ·
Flow: 10000 l / h
Alcoholic strength of the rum to be treated from 32 ° GL to 60 ° GL
Voltage: 110 - 220V three phase
Frequency: 60 Hz
Washing system: Automatic
Must include:
· 1 feed pump.
· 1 tank for Automatic Filter.
· 1 programmer for Filter.
· 1 filter head.
· 1 filter material set for the filter.
· 1 tank for single Softener.
· 1 programmer for Softener.
· 1 head for Softener.
· 1 flow meter for Softener.
· 1 resin set for softener.
· 1 brine tank for Softener.
· 2 AIS I316 ø 63 0 - 10 Bar pressure gauges in glycerin.
· Set of interconnections (Pipes, valves, universal joints, elbows, T, all in AISI 316 stainless steel).
· 1 electrical panel to command the start and stop of the pump, the Head power supply and the Filter and Softener programmers to manage the system after arming.
· Pump - Panel connection cables.
· Filter - Panel, and Softener - Panel connection cables.
· The tanks for feeding and receiving the product to be treated. All connections must be threaded without welding.
· Technical assistance included.
Haiyuan water provide Ion exchange demineralizer with mixed bed advantage
Before and after service
1. To provide oversea service to site help client installation.
2.We are the manufacturer not trader. You can find us solve any problem by online technical team.
3.The Advanced Water Treatment Engineer Certificate issued by The National Professional Center.
4.Professional welded engineer and design engineer and got the certification.
5.All the plant make as per ISO9001 Quality Management System Certificate and SGS Certificate sign.
6. OEM&ODM available.
7. All the plant have been finish complete assemble and testing by Ultrasonic wave detector.
8. The punctual delivery of goods, quality and quantity guaranteed.
9. Reasonable price and good service.
10.We have ourselves brand "JISHUI". And technical patent.
Process introduction of ion exchange
Process flow of ion exchange
NOS. |
Items |
Information |
1. mixed bed demineralizer Pre-treatment part |
||
1.1 |
Sand filter |
Remove turbidity, SS matter, organic matter, colloid, etc. |
1.2 |
Active carbon filter |
Remove color, free chloride, organic matter, harmful matter, etc. |
1.3 |
Water softener |
Soft water and reduce it's hardness. |
2. ion exchange water treatment Deionized water RO part |
||
2.1 |
High pressure pump |
Provide power for RO. |
2.2 |
PP filter |
Prevent large particles, iron, dust, SS matter, impurity into RO membrane. |
2.3 |
RO membrane |
Remves: lead, cooper, barium, chromium, mercury, sodium, cadmium, fluoride, nitrite, nitrate, and selenium. |
3. industrial water treatment Deionized Water System system part |
||
3.1 |
Ion exchange feed water pump |
Provide power for ion exchange system. |
3.2 |
Anion and cation exchange filter |
Further removes ions in water. |
3.3 |
Security fitler |
Prevent the resin leakage |
4. mixed bed demineralizer Electricity control system |
||
4.1 |
PLC+Touch screen control system |
Japan Mitsubishi.siemens |
4.2 |
Electrivity components |
Import from German. Omron. |
4.3 |
Pipe and fitting |
Adopt domestic famous brands. |
Buying Guides for ion exchange demineralizer with mixed bed
To find the most appropriate ion exchange for your use, please have the following information ready
· Product water flow rate ( m3/hr, m3/day, Liter/hr,GPM,GPD etc.)
·· Product water purpose(drinking, irrigation, industry process or others)
· Feed Water TDS (Total dissolved solids). Is it from Borehole/salt/brackish/lake water
· Iron
· Manganese
· TSS(Total Suspended Solid)
· SDI(Silting Density Index)< 3
· Water must be free from oils and grease
· Chlorine must be removed
· Power (110/220/380V/415V/460V, 50 or 60 Hz) 3 phase.
· It is necessary to make water analysis reprot for borehole water,lake water, seawater.
· If soure water is tap water no need end to us TDS or water analysis report.
Send your Inquiry Details in the Below, Click "Send" Now!