Certification: | ISO9001, CE |
---|---|
Salt Rejection Rate: | 99.0% |
Capacity: | Customized From 500~10000L/Hr |
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Haiyuan are professional assembly, production, commissioning water treatment system for 13 years. With CE, SGS, ISO certification. The Quality and Service as our culture. |
We do business with North America, Sourth America, ,The Middle East, Southeast Asia business ,very familiar with different water quality process. |
HY water treatment supply: |
River, pond, stream, canal, sea, lake (Any available surface water and well include any sub surface water source) with TDS value (Max 50000 ppm). |
Tips: one gallon=3.785 liters, 1m3=1ton=1000 liters | |||||
Different Water TDS(Total Dissolved Solids) compare and usage | |||||
Raw water/Application | Bottled water, | City tap water | Industry use (1st level) |
Industry use (2nd level) |
Industry use (3rd level) |
Bag water | |||||
TDS Range | 2-10ppm | 100-1000ppm | Conductivity Range: 1--0.1 μS/cm |
Resitivity Range: 1----10MΩ/cm | Resitivity Range: 10----15MΩ/cm Or more higher: 18 MΩ/cm |
Direct Drinking | Yes | Yes/No | |||
Cooking, human | Yes | Yes | |||
consumption, washing | |||||
Irrigation, Industry, | Yes | Yes | |||
Animal Drinking | |||||
For inudustry use: Condutivity beteen range 1-0.15us/cm or Resitivity 10-18 megohm. Different industry have different water quality requriement. |
|||||
1..Electricity supply:220V-480v, 50hz or 60hz,3 phases 2.Capacity: 500L/H to 50m3/hr. 20ft or 40ft containerized 3.Membranes :DOW(Dupont) or Toray or Vontron 4.UV sterilizer/Ozone generator, CIP washing system, anti-scale dosing system is for optional |
And the process also is difference.
1. Source water tank →Pretreatment parts→ Single RO system→ RO tank→EDI system →DM water system→10MΩ/cm outlet water.
2.Source water tank →Pretreatment parts→ Single RO system→ RO tank→Mixed bed →DM water system→10MΩ/cm outlet water.
3.Source water tank →Pretreatment parts→ doulbe RO system→Double RO tank→EDI system →DM water system→15MΩ/cm outlet water
4.Source water tank →Pretreatment parts→ doulbe RO system→Double RO tank→EDI system →Polish resin filter→ 18 MΩ/cm outlet water
5.Source water tank →Pretreatment parts→ cation resin →anion resin →Middle tank→Mixed bed →DM water→15MΩ/cm outlet water
For DM water output water quality.
1. Conductivity : 1us/cm.
2. Conductivity : 0.1us/cm
3. Resitivity:15MΩ/cm or 18 MΩ/cm
Mixbed bed ion exchanger.
· Consistent high-purity water
· Can handle high variations in feedwater chemistry
· Proven, long operating history
· Most plant operating personnel are familiar with this process
· Requires chemicals
· Chemical feed storage tanks required
· Neutralization process required
Deionized water system
FEED WATER QUALITY AND TREATMENT TECHNOLOGY OF MIXED BED
MIXED BED ION EXCHANGE
Mixed bed ion exchange is an ion exchange process for polishing of demineralised water, meaning for removal of trace dissolved solids from water.
A mixed bed ion exchanger (also: mixed bed polisher, mixed bed filter) is a vessel filled with a mixture of cation exchange resin and anion exchange resin. During service, water flows through this resin mixture. Cations dissolved in the water are then exchanged for hydrogen ions (H+), while anions dissolved in the water are exchanged for hydroxide ions (OH-). Hydrogen ions and hydroxide ions react to water.
With increasing service life, the ion exchange resins deplete. Depleted mixed bed resins are regenerated, usually with both hydrochloric acid (HCl) and sodium hydroxide (NaOH). With each regeneration, potentially acidic or alkaline waste water is produced, which may need to be neutralised. In case of smaller mixed bed exchangers, the ion exchange resin is sometimes also discarded and exchanged once depleted, rather than regenerated.
Usually, a mixed bed ion exchanger is used either as a last polishing step downstream of another demineralisation process, or as a working mixed bed for demineralisation of already partly demineralised or low-TDS water (e.g. condensate).
Process introduction of mixed bed demineralizer
Process flow of mix bed water treatment
NOS. |
Items |
Information |
1. mixed bed demineralizer Pre-treatment part |
||
1.1 |
Sand filter |
Remove turbidity, SS matter, organic matter, colloid, etc. |
1.2 |
Active carbon filter |
Remove color, free chloride, organic matter, harmful matter, etc. |
1.3 |
Water softener |
Soft water and reduce it's hardness. |
2. ion exchange water treatment Deionized water RO part |
||
2.1 |
High pressure pump |
Provide power for RO. |
2.2 |
PP filter |
Prevent large particles, iron, dust, SS matter, impurity into RO membrane. |
2.3 |
RO membrane |
Remves: lead, cooper, barium, chromium, mercury, sodium, cadmium, fluoride, nitrite, nitrate, and selenium. |
3. industrial water treatment Deionized Water System system part |
||
3.1 |
Ion exchange feed water pump |
Provide power for ion exchange system. |
3.2 |
Anion and cation exchange filter |
Further removes ions in water. |
3.3 |
Security fitler |
Prevent the resin leakage |
4. mixed bed demineralizer Electricity control system |
||
4.1 |
PLC+Touch screen control system |
Japan Mitsubishi.siemens |
4.2 |
Electrivity components |
Import from German. Omron. |
4.3 |
Pipe and fitting |
Adopt domestic famous brands. |
Mixed bed water treament demineralizer mixed bed ion exchanger mixed bed Buying Guides
To find the most appropriate mixed bed for your use, please have the following information ready
· Product water flow rate ( m3/hr, m3/day, Liter/hr,GPM,GPD etc.)
·· Product water purpose(drinking, irrigation, industry process or others)
· Feed Water TDS (Total dissolved solids). Is it from Borehole/salt/brackish/lake water
· Iron
· Manganese
· TSS(Total Suspended Solid)
· SDI(Silting Density Index)< 3
· Water must be free from oils and grease
· Chlorine must be removed
· Power (110/220/380V/415V/460V, 50 or 60 Hz) 3 phase.
· It is necessary to make water analysis reprot for borehole water,lake water, seawater.
· If soure water is tap water no need end to us TDS or water analysis report.
Send your Inquiry Details in the Below, Click "Send" Now!