Certification: | ISO9001, CE, SGS |
---|---|
Salt Rejection Rate: | 99.5% |
Application: | Drinking Agriculture or Process Water |
Still deciding? Get samples of $ !
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Containerized Water RO Reverse Osmosis Purification System
Why choose containerized water treatment plant?
![]() |
![]() |
HY-RO-6T/hr container reverse osmosis | |||
Flow rate | 144T/day | Recovery rate | 60% |
Applicable power | 380V/50hz 3 phase | Rated power | 9.9KW |
Feedwater TDS | 2800ppm | freshwater TDS | 31.6ppm |
high pressure | 17.3bar | operating temperature | 5-45ºC |
Feedwater residual chlorine | <0.1ppm | Feedwater SDI | <5 |
Feedwater turbidity | <1NTU | Feedwater PH value | / |
RO membrane housing | 8040*3 core 2pcs | RO membrane | 6pcs |
Variable-frequency Drive | For each pump | Container | 20FT |
All the source water quality is not always the same. This is a short comparison between samples: | ||
Item | source water(Saltness) | Simple TDS range |
1 | Tap water: 0.1-7mg/l | TDS range: 100ppm to 700ppm |
2 | Brackish water:0,7 to 10 g/l | TDS range: 700ppm to 10000ppm |
3 | Northern Sea close to estuaries :21 g/l | TDS range: 10000ppm to 21000ppm |
4 | Atlantic Ocean :35 g/l | TDS 35000ppm |
5 | Mediterranean Sea :38 g/l | TDS 38000ppm |
5 | Arabian Sea :45 g/l | TDS45000ppm |
6 | Red sea: 41g/L | TDS 41000ppm |
7 | Dead Sea :300 g/l. | TDS 300,000ppm |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
Facilities that can be included in the container:
-Solar panels (optional)
-New or second-hand (repaired, painted) container
-Water treatment system (Customize different capacities)
-Control panel
-Explosion proof lights
-Interconnecting piping between components and systems
-Instrument wiring and wiring inside the container to the main control cabinet accordingly
-Non-slip floor covering
-Air conditioning (optional)
-Insulating whiteboard (optional)
-Ventilation fans
Containerized reverse osmosis system have many advantages over built-in plant room installations:
![]() |
![]() |
Tips: one gallon=3.785 liters, 1m3=1ton=1000 liters | ||||
Different Water TDS(Total Dissolved Solids) compare and usage | ||||
Raw water/Application | Bottled water, | City tap water | Brackish water | Seawater |
Bag water | ||||
TDS Range | 2-10ppm | 100-1000ppm | 2000-20000ppm | 20000-40000ppm |
Direct Drinking | Yes | Yes/No | No | No |
Cooking, human | Yes | Yes | No | No |
consumption, washing | ||||
Irrigation, Industry, | Yes | Yes | No | No |
Animal Drinking | ||||
For inudustry use: Condutivity beteen range 1-0.15us/cm or Resitivity 1-18 megohm. Different industry have different water quality requriement. |
||||
1..Electricity supply:220V-480v, 50hz or 60hz,3 phases 2.Capacity: 500L/H to 50m3/hr. 20ft or 40ft containerized 3.Membranes :DOW(Dupont) or Toray or Vontron 4.UV sterilizer/Ozone generator, CIP washing system, anti-scale dosing system is for optional |
Pre-treatment | Feed water pump, Stainless steel | Provide pressure for filters; |
Quartz sand filter | Remove suspended particle and large impurity. In this system; | |
Active Carbon Filter (option) | Remove the color, free chloride, organic matter, harmful matter, ect; | |
Anti-scalant system | To add chemicals to remove some impurities and prolong thememebranes using/washing time(prevent membrane blocking) | |
Manual/Auto control valves | Flushing sand/carbon filter after some time | |
5micron filter | Remove larger than 5 micro colloids in the water. In this system | |
1micron filter | Remove larger than 1 micro colloids in the water. In this system | |
water RO Main Part | High pressure pump, Stainless steel 316L | Provide the high pressure to RO membrane; |
Ro membranes | More than 98% desalination rate, can remove ions except H2O. | |
CIP system | To washing the membranes when it is blocked after using for long time | |
Electronic control panel | PC controller or PLC controller |
Model | Productivity | Motor power | Recovery rate | Outlet water conductivity(us/cm) | Raw water conductivity |
HYRO-500L | 0.5T/H | 1.5kw | 50 | ≤10 | ≤300 |
HYRO-100L | 1T/H | 2.2kw | 50 | ≤10 | ≤300 |
HYRO-2000L | 2T/H | 3kw | 50-60 | ≤10 | ≤300 |
HYRO-3000L | 3T/H | 4.5kw | 55-65 | ≤10 | ≤300 |
HYRO-4000L | 4T/H | 6.5kw | 55-65 | ≤10 | ≤300 |
HYRO-5000L | 5T/H | 8kw | 60-70 | ≤10 | ≤300 |
HYRO-1000L | 10T/H | 15kw | 60-70 | ≤10 | ≤300 |
HYRO-2000L | 20T/H | 22kw | 65-75 | ≤10 | ≤300 |
HYRO-3000L | 30T/H | 26kw | 70-75 | ≤10 | ≤300 |
HYRO-50000L | 50T/H | 55kw | 70-75 | ≤10 | ≤300 |
- We are dedicated in water treatment since 2006
- Direct factory with mature supply chain to offer good price
- Export experience over 30 countries, familiar with customs issues
- Customized water treatment solution for varied industries
- ISO9001 quality certification & OEM service available